Triboelectrochemical Performance of Electron Beam–Melted Ti‐6Al‐4V‐ELI for Biomedical Applications

article
Autores

Pieretti, E. F.

Silva, L. C. E.

Ribeiro, M. S.

De Rossi, W.

Antunes, R. A.

Oliveira, M. C. L.

Piaggio, D.

Cruz, F. P. A.

Da Paz, J. O.

Das Neves, M. D. M.

Data de Publicação

1 de janeiro de 2025

Resumo

Titanium alloys have been widely used for biomaterials’ production due to their high physicochemical stability, mechanical resistance, and biocompatibility. Currently, additive manufacturing (AM) techniques using electron beam melting (EBM) technology have been used to produce implantable medical and dental devices. In the present work, the effect of five different scanning speed on the tribocorrosion behavior of Ti‐6Al‐4V‐ELI (extra low interstitials) alloy was evaluated in Ringer’s saline solution, at 25°C, under a 10‐N normal force in both cathodic and anodic regions to provide a basis for properly deriving the tribological constants of this EBM alloy. A tribometer coupled with a potentiostat/galvanostat, was used to rub the Ti‐6Al‐4V‐ELI disks against alumina balls. The tribocorrosion tests were carried out for 50 min for each sample. The open circuit potential and corrosion current densities were monitored for 10 min, then concomitant with wear tests during 30 min, and finally for more 10 min, without wear. The scratched surfaces were characterized by confocal laser scanning microscopy. The results indicated that the tribocorrosion behavior is influenced by the Ti‐6Al‐4V‐ELI surface finishing. The open circuit potential quickly dropped from −0.55 to −0.75 (V/ Ag/AgCl ) for all samples during tribological application, then returned to nobler values after the application was removed, with the highest values being obtained for Disks 2 and 4. An opposite effect was observed during the chronoamperometry tests. The wear rate depends on the electrolyte, which serves as both a corrosive environment and a tribological lubricant and is closely linked to the speed variation in the EBM manufacturing process. In all cases, the disks produced with EBM scan speed Parameters 1 and 5 showed the highest wear rates.

Citação

BibTeX
@online{e._f.2025,
  author = {E. F. , Pieretti and L. C. E. , Silva and M. S. , Ribeiro
    and Rossi, W., De and R. A. , Antunes and M. C. L. , Oliveira and D.
    , Piaggio and F. P. A. , Cruz and Paz, J. O., Da and Neves, M. D.
    M., Das},
  title = {Triboelectrochemical Performance of Electron Beam–Melted
    Ti‐6Al‐4V‐ELI for Biomedical Applications},
  volume = {2025},
  number = {1},
  date = {2025-01-01},
  doi = {10.1155/amse/8059229},
  langid = {pt-BR},
  abstract = {Titanium alloys have been widely used for biomaterials’
    production due to their high physicochemical stability, mechanical
    resistance, and biocompatibility. Currently, additive manufacturing
    (AM) techniques using electron beam melting (EBM) technology have
    been used to produce implantable medical and dental devices. In the
    present work, the effect of five different scanning speed on the
    tribocorrosion behavior of Ti‐6Al‐4V‐ELI (extra low interstitials)
    alloy was evaluated in Ringer’s saline solution, at 25°C, under a
    10‐N normal force in both cathodic and anodic regions to provide a
    basis for properly deriving the tribological constants of this EBM
    alloy. A tribometer coupled with a potentiostat/galvanostat, was
    used to rub the Ti‐6Al‐4V‐ELI disks against alumina balls. The
    tribocorrosion tests were carried out for 50 min for each sample.
    The open circuit potential and corrosion current densities were
    monitored for 10 min, then concomitant with wear tests during 30
    min, and finally for more 10 min, without wear. The scratched
    surfaces were characterized by confocal laser scanning microscopy.
    The results indicated that the tribocorrosion behavior is influenced
    by the Ti‐6Al‐4V‐ELI surface finishing. The open circuit potential
    quickly dropped from −0.55 to −0.75 (V/ Ag/AgCl ) for all samples
    during tribological application, then returned to nobler values
    after the application was removed, with the highest values being
    obtained for Disks 2 and 4. An opposite effect was observed during
    the chronoamperometry tests. The wear rate depends on the
    electrolyte, which serves as both a corrosive environment and a
    tribological lubricant and is closely linked to the speed variation
    in the EBM manufacturing process. In all cases, the disks produced
    with EBM scan speed Parameters 1 and 5 showed the highest wear
    rates.}
}
Por favor, cite este trabalho como:
E. F., Pieretti, Silva L. C. E., Ribeiro M. S., De Rossi, W., Antunes R. A., Oliveira M. C. L., Piaggio D., Cruz F. P. A., Da Paz, J. O., and Das Neves, M. D. M. 2025. “Triboelectrochemical Performance of Electron Beam–Melted Ti‐6Al‐4V‐ELI for Biomedical Applications.” Advances in Materials Science and Engineering. January 1, 2025. https://doi.org/10.1155/amse/8059229.